Please take a look at our instructional VIDEO.
**PROCEDURE:
- Before every assembly, take out the tank: disconnect 2 tubes from the tank and undo the velcro which attaches the tank.
- Check whether the engine is not hot. We recommend performing the assembly minimum of 0.5 hours after the engine is switched off.
- CHeck whether the ignition is not switched on (the LED must not be lit or flashing)!**
- Unscrew two screws on the drive shaft.
- Unscrew the screw (Allen key 2 mm) on the plastic socket holding the cables.
- Disconnect the connector connecting the timing sensor with the ICU ignition.
- Replace the sensor with a new one.
- Continue with items 3 to 1.
OBSERVE the correct placement of cables!
If the cables are placed incorrectly, there is a danger of damage to the motorized power board.